P.O. Box 208 384 Broyles St. Sparta TN 38583
Phone: 931-836-1212 Fax: 931-836-2002

6 Track Universal Chaser Controller
Model 6TU-18

6 Track Universal Chaser Controller
6 Track Model has 2 different chase mode settings and 3 features.
5 Track Chase Mode
6 Track Chase Mode
Delay Feature
Blank Feature
6 Track Model is able to carry loads up to 360 C7 bulbs per receptacle.


6 Track Universal Chaser Lighting Controllers Examples

Chaser lighting controllers turn on one track at a time.
A 6 Track Universal Chaser has 6 receptacles.
Each receptacle represents one track.
All chaser controllers have a speed control dial.

6 Track Model set in 5 Track Chase Mode

 5 Track Chase Mode
 5 Track Chase Mode activates the receptacles in order.
6 Track Model set in 6 Track Chase Mode

 

 6 Track Chase  6 Track Chase
The receptacles are wired to each of the six deer.
The controller activates the receptacles in order.

6 Track Model with a Delay Feature
 
 Delay Feature  Delay Feature
The example above shows a four step delay.
The delay feature holds a receptacle on for an adjustable period.
The first deer is held on for four steps.
The rest of the deer are on for one step each.

6 Track Model with a Blank Feature

 Blank Feature

The Blank Feature turns all the receptacles off for an adjustable period.
The example above shoes a three step blank.


6 Track Universal Chaser Controller Settings Instructions
Setting a New Chase Pattern
A 6TU-18 will arrive pre-set in 6 track chase. The photograph on the right is a front view of the circuit board located inside the controller.
Note: All settings should be applied with the controller unplugged. Remove screw and the front panel. The dip switch and jumpers are adjustable with needle nose pliers. The dip switch has eight toggle switches. Gently depress the switch that corresponds with the diagram (below) for your desired setting. The jumpers are pulled up and off the posts and pressed into place with pliers.
Light Controller Board
Light Controller Receptacles The controller will turn on the numbered receptacles according to the chase pattern you set.
5 Track Chase
Steps: 5
Pattern: 1, 2, 3, 4, 5 repeat
Settings Diagram
5 Track Chase with a 2 step delay on 5
Steps: 7
Pattern: 1, 2, 3, 4, 5, 5, 5 repeat
Settings Diagram
5 Track Chase with a 2 step delay on 1 and 5
Steps: 9
Pattern: 1, 1, 1, 2, 3, 4, 5, 5, 5 repeat
This setting requires a special order jumper wire.
Settings Diagram
6 Track Chase
Steps:6
Pattern: 1, 2, 3, 4, 5, 6 repeat
Settings Diagram
6 Track Chase with a 2 step delay on 6
Steps:8
Pattern: 1, 2, 3, 4, 5, 6, 6, 6 repeat
Settings Diagram
6 Track Chase with a 2 step delay on 1 and 6.
Steps:10
Pattern: 1, 1, 1, 2, 3, 4, 5, 6, 6, 6 repeat
This setting requires a special order jumper wire.
Settings Diagram
Adding a blank ( all receptacles off ) First achieve a chase setting that you like. Then add blank steps by depressing the next dip switch down. To add a two step blank depress the 2nd to next dip switch down. All chaser controllers have a ten step maximum.
5 Track Chase with 3 step blank
Steps: 8
Pattern: 1, 2, 3, 4, 5, off, off, off repeat
 
Settings Diagram

                 
Login for Customer Service and Order Tracking